This is an old revision of the document!
This timer writes a process variable and forwards an instance based on the activity name and transition name.
IMPORTANT! This mostly used in combination with the decision by e-mail.In this case, the Webservice to be executed as SOAP-call. Using this as a completely configured timer in the admin client makes little sense.
ProcessInstanceManager
setProcessVariableAndSignalProcessInstanceByTransitionName
ProcessInstanceId
Link call up: args[0](see Example)
Variables name
Link call up: args[1] (see Example)
Variables value
Link call up: args[2] (see Example)
Activity name
Link call up: args[3] (see [[#Example])
Transition name
Link call up: args[4] (see [[#Example])
uid: Encoding login data for TIM Base64 (client/user:password)
http://URL of the Server/loom-portal/ProcessInstanceManager/setProcessVariableAndSignalProcessInstanceByTransitionName.soap?args[0]=${processInstanceId}&args[1]=VARIABLESNAME&args[2]=VARIABLESVALUE&args[3]=ACTIVITYNAME&args[4]=TRANSITIONNAME&i=1&uid=LOGINDATA